Sistemas multicanal

Dual View Simultaneous Imaging Systems

DC2DC2 Multichannel Imaging System

Two-Channel, Full-Field, Simultaneous-Imaging System

The DC2 is an emission splitting system enabling a user to acquire 2 spatially identical but spectrally distinct images simultaneously. Simultaneous, multichannel imaging is essential to directly compare each of the two image channels. This comparison can be in the form of colocalization analysis, emission ratiometric analysis or polarization studies of single wavelength channel. read more

Primary Applications
  • High Content Screening
  • Multicolor TIRF
  • Polarization/Anisotropy
  • Fluorescence Biosensors
  • FRET
  • Simultaneous Fluorescence/DIC

DDV2V2 Multichannel Imaging System

Two-Channel, Simultaneous-Imaging System

The DV2 is an emission splitting system enabling a user to acquire 2 spatially identical but spectrally distinct images simultaneously. Simultaneous, multichannel imaging is essential for researchers needing to directly compare each of the two image channels. This comparison can be in the form of colocalization analysis, emission ratiometric analysis or polarization studies of single wavelength channel. read more

Primary Applications
  • Multicolor TIRF
  • FRET
  • Polarization/Anisotropy
  • Fluorescence Biosensors
  • 3D particle tracking via Bifocal Imaging
  • Simultaneous Fluorescence/DIC

DVLambdaDVΛ Multichannel Imaging System

Two-Channel, Simultaneous-Imaging System for Large Format Sensors

The DVΛ is an emission splitting system enabling a user to acquire two spatially identical but spectrally distinct images simultaneously. What distinguishes the DVΛ from the DV2 is that DVΛ can accommodate image sensors up to a 22 mm diagonal. Simultaneous, multichannel imaging is essential for colocalization analysis, ratiometric analysis, or polarization studies of a single emission wavelength channel. read more

Primary Applications
  • Multicolor TIRF
  • FRET
  • Polarization/Anisotropy
  • Fluorescence Biosensors
  • 3D particle tracking via Bifocal Imaging
  • Simultaneous Fluorescence/DIC

Quad View Simultaneous Imaging Systems

QV2QV2 Multichannel Imaging System

Simultaneous Acquisition of up to Four Emission Channels

The QV2 allows simultaneous acquisition of up to four emission channels in a single exposure. The QV2 uses a series of beamsplitters to split the emission light from the microscope into four separate channels. Each channel is then projected onto one quadrant of the CCD at exactly the same moment in time. Simultaneous multichannel imaging is essential to achieve quantitative ratiometric imaging. read more

Primary Applications
  • Three-color fluorescence and DIC
  • Two-color polarization/anisotropy studies
  • Simultaneous calcium and pH studies with indo-1 and SNARF
  • FRET
  • Quantum Dot Imaging